WARNING
Avoid Electrical Shock Hazard!
Do not work on an energized circuit. Doing so could
result in serious injury or death. Only qualified electricians
should perform electrical work. Do not attempt any work
on the dishwasher electric supply circuit until you are
certain the circuit is de-energized.
To avoid possible injury or property damage, care should
be exercised when the dishwasher is installed or removed
to reduce the likelihood of damage to the power cord.
Avoid Fire Hazard!
Make sure electrical work is properly installed and
checked by qualified electricians.
Make sure there are no loose electrical connections. Make
sure all electrical connections are properly made.
Loose and improperly installed electrical connections
can result in overheating!
To avoid risk of fire, observe the following precautions:
Wall Socket Connections:
Only use the provided power cord for wall socket
connections.
DO NOT attach an extension cord or any type of modified
cord or adapter with this appliance.
DO NOT cut or splice the power cord.
DO NOT alter the power cord in any way.
Permanent Wire Connections (in addition to the
warnings above):
Only use the junction box power cord, sold as Accessory
kit #SMZPCJB1UC.
Carefully review the terminal block installation instructions.
DO NOT remove, alter or bypass the terminal block.
Electrical Supply
The customer has the responsibility of ensuring that the dish-
washer electrical installation is in compliance with all national
and local electrical codes and ordinances. The dishwasher is
designed for an electrical supply of 120V, 60 Hz, AC, connect-
ed to a dishwasher-dedicated, properly grounded electrical cir-
cuit with a fuse or breaker rated for 15 or 20 amps.
Dishwasher Electrical Rating
Volts Hertz
120
60
Electrical Preparation
Amperes
Watts
12
1,440
(max)
Grounding Instructions
The dishwasher must be properly grounded before operat-
ing. This appliance must be connected to a grounded metal
permanent wiring system
or an equipment grounding conductor must be run with the
circuit conductors and connected to the equipment grounding
terminal or lead on the dishwasher.
Do NOT use an extension cord.
Make sure that the dishwasher is connected to a suitable
ground in compliance with all local codes or, in the absence of
a local code, with the NATIONAL ELECTRICAL CODE in the
United States or the CANADIAN ELECTRIC CODE C22.1-
latest edition in Canada as well as any provincial/state or
municipal or local codes that apply.
Note: Installations requiring hard wiring and terminal
block - The accessory terminal block/junction box model,
SMZPCJB1UC, designed for permanent wire connection, is
not included but can be ordered through Customer Service by
calling 1-800-944-2904. Follow the instructions included with
the kit.
Figure 6
•
Place adhesive backed cord clips (provided in the
installation kit) as shown in the figure above and route
power cord through the clips. If the power cord will be
assembled to the right side, loop the cord as shown
above. If the power cord will go the left side, place the
clips as shown above for the left side.
•
Plug the end of the supply cord into the back of the
dishwasher.
•
The outlet for the power supply cord should be located in
a cabinet or wall adjacent to the dishwasher cabinet. Do
not plug dishwasher in until all the steps of installation are
complete.
Note: Only use the included power cord. If cord is missing
order kit SMZPC002UC through Customer Service.
7