CONTROL LOCATION

The on-board control can be located on the top of the
dehumidifier or can be relocated to the front of the
dehumidifier if the control cannot be seen/accessed in
the top orientation . It may also be rotated 180 degrees
in either orientation as shown in FIGURE 6 .
To move the control:
1. Remove the front control panel cover .
2. Remove the filter access door and filter .
3. Detach the on-board control by removing the four
(4) screws around the control . NOTE: Use one hand
to support the bottom of the on-board control
when removing .
4. Keep the control in the unit and relocate to the front
access hole .
5. Secure the control with the same four screws used
to attach the control to the top of the unit .
6. Secure the control panel cover to the top of the unit .

LOCATION CONSIDERATIONS

• Allow sufficient clearance for filter removal and to
prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown . Allow sufficient space for
service on this side of the unit .
• When suspending the unit, a condensate pan
with float switch is recommended to prevent any
leaks that may occur due to unforeseen drain line
obstructions .
FIGURE 5 – CONTROL LOCATION
CONTROL
CONTROL
PANEL COVER
FIGURE 6 – CONTROL ROTATED 180 DEGREES
FIGURE 6 – FILTER ACCESS CLEARANCE
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
FILTER
TOP VIEW
CONTROL
PANEL COVER
CONTROL
FILTER ACCESS DOOR
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
15"
MINIMUM
CLEARANCE FOR FILTER
(BOTH SIDES)
90-1884
90-2525
90-1840