Commercial Power Amplifier
INPuT WIrINg
Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The
use of crimp type spade lugs is highly recommended for permanent installations. At the input
section located on the rear of the amplifier, wire the "hot"/positive lead to the "+" terminal, the
"common"/negative lead to the "-" terminal and the shield/drain to the "ground" terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female
patch cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is
used as a portable sound system amplifier.
AtlasSound.com
CP400 & CP700
White (+)
Black (-)
Shield
IN
AMPLIFIER INPUTS
CH-2
+
THRU
LEVEL
GND
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Specifications are subject to change without notice.
POWER
White (+)
Black (-)
Shield
CH-1
-
GND
-
+
LEVEL
STEREO
PARALLEL
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
Telephone: 800.876.3333 • Fax: 800.765.3435
– 7 –
Owner's Manual
IN
THRU
Figure 3
BRIDGE