DROPSA SUMO II Series Kullanım ve Bakım Kılavuzu - Sayfa 7

Su Pompası DROPSA SUMO II Series için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. DROPSA SUMO II Series 13 sayfaları.

DROPSA SUMO II Series Kullanım ve Bakım Kılavuzu
7.3
ADJUSTMENT/ CALIBRATION OF LEVEL PROBES
7.3.1 LASER PROBE SETTING 0295131, 24V cc Out NO and NC (1 threshold)
* To obtain a correct setting bring the lock ring to maximum setting value and then down to desire value.
On the pump is placed a label that shows the wiring diagram and setting values. The pump is normally equipped with pre setting
sensor to "L" thresholds (minimum level). Whereas other thresholds: MM (absolute maximum level), M (absolute level), LL
(absolute minimum level), can be set
Attention you can only set one thresholds at a time
7.3.3 Procedure for calibrating the laser probe 24V cc Out 4÷20mA/2 NO (4 thresholds)
The laser probe possesses a representative and programming display mounted on board. It is possible to operate in analogue
mode (with signal from 4 to 20 mA) or in digital mode (two outputs and four intervention thresholds).
We attach a table showing the calibration parameters for the laser probe.
Image 6
NOTE: To change calibration thresholds of laser and ultrasound probes contact DROPSA staff
7.3.4 Collegamento galleggiante REED 0295150/0295160
Pos.
Level
Output
signal
A
Maximum
absolute level
OUT 2= Fno
C
Minimum level
B
Maximum level
D
Minimum
OUT 1= Fno
absolute level
1.
Reference notch
2.
Yellow led: lights when the set value is reached, (outlet=ON).
3.
Lock ring
4.
Setting lock ring (be adjusted manually after unlocking).
5.
Green led: indicates the correct power supply (24V cc).
LASER PROBE CALIBRATION
100 kg reservoir
set-up
height X
[mm]
nsP2
220
fsP2
300
nsP1
250
fsP1
330
30 kg reservoir
Quantity of
height X
Quantity of
grease [kg]
[mm]
grease [kg]
90
220
17
490
86
250
14
520
23
5
21
3