10 Safety Devices Operation
NOTE: The motor has an overheating protection device built in.
It will automatically switch off power to the motor if it overheats. e.g. from
blocked nozzles, full dust Canister or uncleaned and blocked filters.
If this happens, turn off the vacuum cleaner and unplug from the power socket,
clean blockage and / or filters and allow to rest for at least 60 minutes which
should be enough time for the motor to cool down.
Important: If the over-temperature device activates and turns the motor off,
and you do not switch off and unplug the appliance from the power point, the
motor will restart automatically after it has cooled down enough to reset the
safety device.
NOTE: NEVER BLOCK ANY VENTS OR OPENINGS.
11 Emptying the Dust Canister
Empty the Dust Canister before the dust level reaches the MAX line, or when
the suction power is reduced.
To remove the Dust Canister, turn off the power, unplug and
•
disconnect the vacuum hose.
•
Grip the handle on the Dust Canister, press the
Dust Canister Release Button and pull the Dust
Canister forward and out of the housing.
Take the dust container to a dustbin.
•
Press the Trap Door release button downward to
•
release the latch and the trap door will swing open
emptying the contents into the bin.
To close the trap door, close it manually until it clips
shut.