Absolon IRENE BASIC Talimatlar Kılavuzu - Sayfa 2
Güvenlik Sistemi Absolon IRENE BASIC için çevrimiçi göz atın veya pdf Talimatlar Kılavuzu indirin. Absolon IRENE BASIC 6 sayfaları. Autonomous outdoor siren
GENERAL FEATURES
To make the installation process easier, it is not necessary to connect the power supply for the
alarm panel directly (in cases that the siren is placed before the panel.
5 different sound types
3 different sound volumes (high / progressively rising / low)
the five central LEDs have 14 modes of flashing into standby mode.
the side LEDs have 5 ways of flashing when the "FLS" is triggered
1 "TRG" input for variable sound emission and flashing
1 "FIRE" input for steady sound emission and flashing
the TRG / FIRE / FLS input modes are dependent on the choice of the Dip Switch No1 & No2:
1. LOSE (-) By breaking the negative voltage
2. LOSE (+)By breaking the positive voltage
3. GO (-) By application of negative voltage
4. GO (+) By application of positive voltage
Βattery protection from reverse polarity with LED light
Τrue Low Battery error at "LB" output, showing a positive voltage when the battery voltage is below
10.2V. Resetting the output to normal mode is done after 45sec and if the battery voltage rises
above 10.2V.
In the event of a power failure, the siren is activated and beeps depending on the programming via
the Dip switch selected by the installer (selected).
Cover protection in the case of opening and removal from the wall (selected by Dip switch).
"RST TMP" (reset tamper) input to temporarily turn Tamper off if we want to open the siren cover and
change the battery. Apply positive voltage to the "RST TMP" input for as long as the siren cover is open.
Additional12V buzzer place for extra audio updates (eg arming-disarming).
"ALARM OUT" output. Auxiliary output. There is another output for the activation of other applications, such
as headlights.
The siren can also be used without its battery.
SPECIFICATIONS
Rated voltage
Consumption at rest
Consumption while the siren is activated
Operating frequency
Buzzer level
Consumption of LED FLASH
TAMPER protection switch
Contact switch TAMPER N.C/N.O
Duration of the TAMPER alarm
Inputs
Leakage level
Battery
Weight
Dimensions
IRENE
12-14V DC
6-20mA (depending on the LED mode)
460-600mA with battery/760-900mA without battery
900-3500Hz
125Db/1 meter
15x20mA
On the cover and on the wall
600mA/125V DC
90 sec
by applying or breaking the positive or negative voltage
IP 44
12v/1,2 or 2,3 Ah
1800 grams
250/350/80 mm (LxHxW)