12V-/+
TRG
FIRE
GND
RST TMP
FLS
LB
TMP OUT
ALARM OUT
DIP SWITCH No1 (+/-)
DIP SWITCH No2 (LOSE/GO)
DIP SWITCH No3 (TMP/OFF)
DIP SWITCH No4 (DC/OFF)
Power supply of the siren from the panel
Primary input for the activation of the sounder and central LEDs (BELL)
from the panel (the mode of activation is dependent on DIP SWITCH 1 &
DIP SWITCH 2)
Secondary input for the activation of the sounder and central LEDs
(FIRE) from the panel (the mode of activation is dependent on DIP
SWITCH 1 & DIP SWITCH 2)
0V
By continuous application of (+) from the panel, we switch off the
siren's TAMPER so we can change the battery to the siren-SERVICE
Input for the activation of LED side panels from the panel (the mode of
activation is dependent on DIP SWITCH 1 & DIP SWITCH 2)
low battery error output with positive output when battery is
discharged below 10,2V
TAMPER of the siren, alarm output -0V
Auxiliary ALARM output which, at the same time as the siren is turned
on, also has an output for activating another device, e.g. Headlamps
(applied -0V cut off during alarm)
DIP SWITCH EXPLANATION
Choice of positive or negative voltage activation at the TRG
/ FIRE / FLS inputs.
Voltage activation option for TRG / FIRE / FLS inputs
(voltage application or continuous voltage cut-off).
Option to enable or disable electronic TAMPER.
Option to enable or disable siren activation when the siren
supply is cut off from the panel (eg cable cut)