Opening/Closing By Wireless Key Reporting
NOTE
NOTE: The Identified Wireless Key Closing option is only available with the PC5020, P-
NOTE
NOTE
NOTE
8+, PC501X v2.0 and higher, P832/DL v2.0 and higher, PC1555(MX), P-6B(MX), PC580
v2.0 and higher, P-48 v2.0 and higher by turning section [015] option 4 off.
To enable the reporting of openings and closings by identified wireless keys:
• Make sure the control panel is v2.0 or higher
• Program a valid access code for each key
• Program a closing and opening reporting code for each key's access code
• Turn off the Quick Arm option in section [015] option [4] of the control panel
programming
To ensure that an unidentified wireless key cannot disarm the system, turn off section
[017], option [1] (in the control panel programming). This option is available in control
panels with software version 2.1 or higher.
Command Output Activation
NOTE
NOTE
NOTE: The Identified Wireless Key Command Output Activation feature is only available
NOTE
NOTE
with the PC5020, P-8+, PC501X, P832/DL, PC1555(MX), P-6B(MX), PC580 v2.0 and higher
and P-48 v2.0 and higher.
To enable command output activation by wireless keys, ensure that:
• The control panel is v2.0 or higher
• Program a valid access code for each key
• Enable the PGM output attribute Requires Access Code for each PGM output
programmed as [✱][7][1-4] in sections [141] to [154].
Now that you have enrolled all the wireless keys, you will need to program the system to
work properly with the keys. See section 4 for more information.

Section 4: Other Programming

Section 4: Other Programming
Section 4: Other Programming
Section 4: Other Programming
Section 4: Other Programming
4.1
PC5102 PGM Outputs
The PC5102-433 has two on-board Form C relay PGM outputs. Each of these can be
individually programmed to:
1. Follow main panel PGM outputs 1 to 14.
NOTE: Please refer to your System Installation Manual for available PGM outputs.
NOTE: If the PC5102-433 is connected to the PC580/PC1555/P-48/P-6B (all versions),
PC5010 v1.x, P832 v1.x or the WSS5010 1.0, 2.1, the PC5102 PGM outputs cannot be
programmed to follow main panel PGM outputs 1 or 2.
2. Activate for a programmable amount of time when a signal is received from a
wireless key programmed with output option 31 or 32 (PC5102 PGM pulse) and the
PGM output programming section [92] or [93] is programmed with option 15
(PC5102 PGM pulse). The amount of time that the PGM outputs can be
programmed to remain on is programmed in sections [94] and/or [95]. The default
activation time is 5 seconds.
3. Toggle state when a signal is received from a wireless key programmed with option
31 or 32 and the PGM output programming section [92] or [93] is programmed
with option 16 (PC5102 PGM toggle).
4.2
Enable PC5102-433 Supervision
The control panel will supervise the PC5102-433 receiver via the Keybus after at least one
key has been enrolled on the module (see section 3.2 "Enrolling Wireless Keys").
To activate module supervision, after you enroll the first key(s):
1. Exit and then re-enter installer's programming.
2. Enter programming section [902]. Wait approximately one minute.
3. To exit press [#].