airweigh LoadMaxx 5809 Kullanıcı Kılavuzu - Sayfa 6
Terazi airweigh LoadMaxx 5809 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. airweigh LoadMaxx 5809 16 sayfaları. For tractors with a hydraulic lift
Calibrating The Tractor Scale Overview
The order of calibration is not important; however, both EMPTY and
HEAVY weights must be properly entered before the weight display
is accurate. When calibrating, the EMPTY weights must be entered
while the vehicle is empty, and the HEAVY weights must be entered
while the vehicle is fully loaded. Failure to calibrate scales when
vehicle is actually empty and when it has a true heavy load will result
in inaccurate weights.
Calibrating Empty Weights
Leave the 5th wheel plate at the lowest position on stoppers.
1. Press ESC one or more times until the Main Menu appears,
with VIEW WEIGHTS blinking
2. Select PRINT,SETUP
3. Select SYSTEM SETUP
4. Select CALIBRATION
5. Select MANUAL CALIBRATION
6. Select EMPTY WEIGHT
7. The screen pauses for three seconds with
the display, "ENTER EMPTY – VEHICLE
MUST BE EMPTY" before proceeding automatically to the next
menu
8. On the PICK AXL menu, select DRV (Drive) for the hydraulic lift
9. Using the up/down arrows ▲ or ▼ , enter 20lbs. for your
EMPTY weight and press ENTER. The screen will briefly show
Accepted to indicate its acceptance of the Empty Weight
4
If PIN is needed for access, enter it at this time