2. INSTALLING PROCEDURE
2-4. Checking the Suction Collator EPROM
1
Check the version of the EPROM in the ROM number check mode of the suction collator.
(1) Press the numerical keys on the control panel in the following order. 1 → 2 → 3 → 4 → 5 → 6
(2) Press the STOP key. The ROM number will be displayed on the display window as follows.
For the DC-10000S
"A-?"
↓
Press the STOP key.
"b-?"
↓
Press the STOP key.
"C-?"
↓
Press the STOP key.
"d-?"
↓
Press the STOP key.
"E-?"
↓
Press the STOP key.
"F-?"
↓
Release the check mode using the STOP key.
∗ For DC-6000S, up to "C-?" will be displayed. For DC-8000S 2, up to "d-?" will be displayed.
→ If the version is 99L-80212 or more, it need not be replaced.
DC-6000S
DC-8000S 2 → If the version is 96F-82498 or more, it need not be replaced.
DC-10000S → If the version is 96F-81999 or more, it need not be replaced.
NOTE
:
The DBM-120 will not operate normally with EPROMs of versions below the versions indicated above.
Use the same EPROM versions for all towers connected.
The EPROM is a service parts.
6
Display the ROM number of Tower A.
Display the ROM number of Tower B.
Display the ROM number of Tower C.
Display the ROM number of Tower D.
Display the ROM number of Tower E.
Display the ROM number of Tower F.