Audiophonics DA-S250NC Kullanıcı Kılavuzu - Sayfa 13
Amplifikatör Audiophonics DA-S250NC için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Audiophonics DA-S250NC 14 sayfaları.
Ayrıca Audiophonics DA-S250NC için: Kullanıcı Kılavuzu (14 sayfalar)
Settings
To enter the unit's configuration screen, press the Select button (17) on the remote control. Five settings appear on the screen (4). Use the Up (18) and Down (22)
navigation buttons on the remote control to select a setting. Press the Enter Button (19) on the remote control to enter the selected setting.
1. Max output level
This parameter allows to change the gain attenuation level of the amplifier and the DAC. The following settings are available :
1. 0dB (default)
2� ‑6dB
3� ‑12dB
4� ‑18dB
Note: The volume display on the screen does not reflect the use of this setting.
Example: If you select a gain attenuation level of -6dB and set the volume level to -30dB on the display, then the actual attenuation level is -36dB.
2. PCM filter
This parameter allows you to select a digital PCM filter to adjust the sound of the device. Four filters are available:
1. Apodizing Fast (default)
2. Fast linear
3. Slow linear
4. Fast minimum
Apodizing Fast (dB)
Fast Linear (dB)
Slow Linear (dB)
Fast Minimum (dB)
12
EN