CASSENS & PLATH CAMcourse Kurulum ve Kullanım Kılavuzu - Sayfa 6

Pusula CASSENS & PLATH CAMcourse için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. CASSENS & PLATH CAMcourse 9 sayfaları.

Main Indicator
(Measures Junction Box 1: w125xh80xd60mm)
Screening of cables have to been fixed
in cable glants!
Camera
(Measures Junction Box 2: w100xh65xd35mm)
Alterations / Errors Reserved
Cassens & Plath GmbH, Am Lunedeich 131, D-27572 Bremerhaven, Germany, tel +49(0)471 483 999 0, fax +49(0)471 483 999 10
www.cassens-plath.de,
To Monitor:
1) +12V DC
2) GND
3) GND
4) Video
To 2nd Monitor (optional):
5) +12V DC
6) GND
7) GND
8) Video
To Junction Box 2 (Camera):
9) +12V DC
10) GND
11) GND
12) Video
Cable, yard supply!:
4x0.14² min., twisted pairs, shielded, max. 40m
Power supply:
13) +24V DC
14) GND
15) +24V DC emergency
16) GND
Emergency supply (15 + 16) only needed if
seperated from main supply (13 + 14).
Cable, yard supply!:
2x0.25² min., twisted pair, shielded, max. 5m
(2 pieces for main- and emergency supply)
To Junction Box 1 (Monitor):
1) Video (yellow)
2) GND (white)
3) GND (black)
4) +12V DC (red)
Cable, yard supply!:
4x0.14² min., twisted pairs, shielded, max. 40m
(refer junction box 1)
CAMcourse
Page 6
16/Wo/266D