Apollo 7100UL Kurulum Kılavuzu - Sayfa 15
Kapı Açıcı Apollo 7100UL için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Apollo 7100UL 17 sayfaları. Residential & medium duty commercial slide gate operator
833/834 CONTROL BOARD ADJUSTMENTS
OFF
ON
Program Switch #9
"Learn Mode"
Learn Mode
When switch #9 is in the 'ON' position, the controller is in learn mode. Learn mode is used to 'train' the
controller on the installation. Specifically the controller monitors the current draw and stroke length during
learn mode. This allows the controller to automatically set the auto reverse sensitivity of the installation in
addition to determining when to engage the soft stop feature.
When the controller is initially installed, it must be put into learn mode. The gate should be fully opened
and closed 3-5 times and partially opened and closed 3-5 times to allow the controller to adjust to the
weight and size of the gate. Program switch #9 should then be moved to the 'OFF' position to exit learn
mode.
Any changes to the condition of the gate (i.e. cold weather, rust, etc.) may require the controller to be put
into learn mode to train the controller once again.
Note: The controller must be put into learn mode any time that it is disconnected from the power supply.
Switch #9 Must Be In The OFF Position During Normal Operation.
14