Elsema G-2000 Manuel - Sayfa 9

Alıcı Elsema G-2000 için çevrimiçi göz atın veya pdf Manuel indirin. Elsema G-2000 13 sayfaları. 3g receiver with relay output for opening sliding, swing gates, doors or switching devices

Elsema G-2000 Manuel
 Setup Relay OFF delay
PwdGOTclose time#
o
The relay OFF delay can be set from 000-999 seconds. The factory default is 0.5 seconds.
000—0.5 second
999— Latching mode. Relay will stay ON until a second call is made.
E.g. If the relay OFF delay needs to be set at 10 seconds, the following command is needed
1234GOT010#
Relay will stay ON for 10sec once activated.
 SMS confirmation of relay switching
This feature enables the 1
ON or OFF.
For relay ON you need the following command
PwdGONab#content#
o
For relay OFF you need the following command
PwdGOFFab#content#
o
Ab is the option for the 1
switching. Have a look at the table below:
A (First user)
Content is the SMS message which the user and the caller will receive.
st
E.g. If only the 1
command is needed
1234GON10#gate open#
st
E.g. If the 1
user and the caller both are required to receive SMS "gate closed" when the relay is OFF, the
following command is needed
1234GOFF11#gate closed#
If SMS is not required for any users when the relay is ON the following command is needed.
PwdGON##
o
If SMS is not required for any users when the relay is OFF the following command is needed.
PwdGOFF##
o
www.elsema.com
st
user and the person making a call to get SMS confirmation of the relay switching
st
user and the caller to either receive or not to receive SMS confirmation of the relay
AB Option
B (Caller)
0
0
0
1
1
0
1
1
user is required to receive SMS "gate open" when the relay is ON, the following
SMS Confirmation to user
st
1
user
Page 9
ELSEMA
3G Receiver with relay output, G-2000
Caller