Power Supply
Power can be supplied to the scanner through the pins provided on the
25-pin connector used for communication with the host.
The power must be between 10 and 30 Vdc only.
SCANNER
13/9
VS
25
GND
1
CHASSIS
Inputs
The yellow LED is on when the External Trigger forces a current flow
through the EXT TRIG+ and EXT TRIG- pins.
This input is optocoupled and can be driven by both an NPN or PNP type
command. The connections are indicated in the following diagrams:
SCANNER
+ 5V
18
EXT TRIG+
19
EXT TRIG-
Figure 2 - Input NPN command using external power
SCANNER
9
+ 5V
18
19
25
Figure 3 - Input NPN command using scanner power
USER INTERFACE
V+ (10 - 30 Vdc)
GND
Vext
30 Vdc max.
EXTERNAL TRIGGER
V
Signal
EXTERNAL TRIGGER
VS
V
EXT TRIG+
EXT TRIG-
Signal
GND
Ground
SCANNER
+ 5V
18
EXT TRIG+
19
EXT TRIG-
Figure 4 - Input PNP command using external power
SCANNER
9
+ 5V
18
19
25
Figure 5 - Input PNP command using scanner power
For DS1100, the general purpose input IN1 is used in the Standard
Application Program to store the code verifier (see "Store Verifier HW" in the
WinHost Help On Line). Use the input connections indicated in the figure
below. For DS2200, this input is not used.
SCANNER
13/9
VS
47 K
17
IN1 -
I/O REF
22
Figure 6 - IN1 - Input command
Vext
30 Vdc max.
EXTERNAL TRIGGER
V
Signal
Ground
EXTERNAL TRIGGER
VS
V
Signal
EXT TRIG+
EXT TRIG-
GND
Ground
USER INTERFACE
V
Ground