Datcon DT1600 U Series Kullanım Talimatları Kılavuzu - Sayfa 16
Verici Datcon DT1600 U Series için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Datcon DT1600 U Series 20 sayfaları. Ac voltage transmitters
16
8. Calculation for application
8.1. Calculations
Calculating the input voltage from the transmitter output
signal.
U
[V]: voltage to be measured
X
n: voltage transformer ratio
(in case of direct connection n = 1)
U
[V]:
IN
I
[mA], U
[V]: transmitter output signal
OUT
OUT
In case of I0, U10 outputs:
U
= n * U
* I
X
IN
OUT
st
1
example:
I
= 250 V
IN
I
= 10 * 250 * 18 / 20 = 2250 V
X
In case of I4 output:
U
= n * U
* (I
X
IN
OUT
nd
2
example:
I
= 250 V
IN
I
= 10 * 250 * (12-4) / 16 = 1250 V
X
transmitter input voltage
/ 20
U
= n * U
X
I
= 18 mA
OUT
- 4) / 16
I
= 12 mA
OUT
DT1600 Ux xx xx
* U
/ 10
IN
OUT
n = 10
n = 10
20180621-V0