Mounting

Note: If the dispense valve is to be mounted in an area that limits access to the valve, it
is recommended that the set-up operation be done prior to mounting. Access to
various surfaces of the valve is necessary for periodic adjustment (see Specifications).
There is a 0.25" [0.64 cm] mounting hole through the side of the dispense valve for
mounting purposes (see Figure 8).

System Interconnect

Air
Once the dispense valve is secured to its mounting surface, connect the air lines to the
ports provided on the valve (Figure 4). Connect the air supply (75-100 psi [5.1- 6.9 bar])
to the valve controller or 4-way solenoid valve.
Figure 4.
Air-In Port
Air-In Port (Normally Open)
Air-In Port (Normally Open)

Valve Adjustments

Adjusting Material Flow
To adjust the flow of the Model 828 valve, turn the Pinch-Piston Flow Adjustment Screw
(Figure 5, A) clockwise to decrease material flow or counterclockwise to increase
material flow.
U S E R G U I D E
M O D E L 8 2 8 D I S P E N S I N G V A L V E
10
|