AgriEid Cattle Scales Kurulum Kılavuzu - Sayfa 3

Terazi AgriEid Cattle Scales için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. AgriEid Cattle Scales 6 sayfaları.

AgriEid Cattle Scales Kurulum Kılavuzu
Step 4 : Each load cell has 3.5m of cable. Each of the 4 cables is
screwed into the appropriate position on the junction box which must
match the load cell position on the platform (see below).
The digital weight indicator has a 3.5m quick connect cable that is
connected to the center slot on the left hand side of the junction box
(cable with a
Red
rubber seal and marked
E
below).
Connect the Digital Weigh Indicator cable to the center slot on left provided (as above)
Connect load cell cables in this colour order: Black, White, Yellow, Green Red
Load cells are positioned on the platform (see below) to match the ABCD cell wiring (above)
A and B - FATHEREST LOAD CELLS FROM JUNCTION BOX
D and C - CLOSEST LOAD CELLS TO THE JUNCTION BOX