AgriEid Cattle Scales Kurulum Kılavuzu - Sayfa 4

Terazi AgriEid Cattle Scales için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. AgriEid Cattle Scales 6 sayfaları.

AgriEid Cattle Scales Kurulum Kılavuzu
Step 5 : CALIBRATION :
Once the individual load cells have been firmly bolted to the platform
and the cables connected you will need a test weight to check and
calibrate the indicator to be sure it is delivering an accurate reading.
If the displayed weight is not correct complete the following simple
calibration to get the system operational.
Stand on the platform using your own body weight or the person who
may be assisting you.
To Open the Main Menu – press HOLD AND PRINT AT SAME TIME
To Navigate Up and Down – use Tare and Zero buttons
(see arrows below buttons in diagram below)
To Navigate Left and Right – use Count and Gross
(see arrows below buttons in diagram below)
To Enter – use the Print button
(see diagram below)
To Exit – use the Total button
(see diagram below)
To go Back – use the Hold button
(see diagram below)