Ayrıca ADEMCO Ademco VISTA-20P için: Hızlı Kurulum Kılavuzu (2 sayfalar), Programlama Kılavuzu (17 sayfalar), Kullanıcı Kılavuzu (20 sayfalar), Programlama Kılavuzu (17 sayfalar), Hızlı Kurulum Kılavuzu (2 sayfalar), Hızlı Kurulum Kılavuzu (2 sayfalar), Programlama Kılavuzu (2 sayfalar), Hızlı Kılavuz (2 sayfalar)

ADEMCO Ademco VISTA-20P Hızlı Başlangıç Kılavuzu
Step 8: Confirmation of Arming Ding (*38) (Page 4-2 in the Installation and
Setup Guide)
 Note: You do not need to enter *38 if you have just completed step 7.
 Enter:
o 00=No Ding
o 01=Ding after Arming
o 02=Ding after arming with RF button or RF keypad
Step 9a: Hardwired Zone Programming (*56) (Page 5-1 and 5-2 of the
Installation and Setup Guide)
 Enter *56
 Set to Confirm will be displayed on the screen. This means: Are you
installing wireless devices?
o
0=NO and 1=Yes
Zone 1 is for Fire or any hardwired device if fire is not being used
Zones 2-8 hardwired devices
Zones 9-48 Wireless Transmitter Zones
Zones 49-64 Key Fobs
Zone 92 Duress
Zones 95, 96, and 99 are Panic Zones
Zone Types:
00= Not Used 04= Interior follower 08= 24 Hr Aux 21= Arm-Away
01=Entry/Exit #1 05=Trouble Day/Alarm Night 09=Fire no delay 22=Disarm
02=Entry/Exit #2 06=24 Hr Silent 10=Interior delay 23=No Alarm Response
03=Perimeter 07=24 Hr Audible 20=Arm Stay 24=Silent Burglary
 Enter the Zone Number you wish to program and press *. A summary
screen will be displayed. Press * again to advance past the summary
screen.
 Enter the Zone Type (ZT). (Refer above or go to page 5-2 in the
Installation and Setup Guide for the exact types). Press * to continue.
 Enter the partition number (PT 1 or 2). (NOTE= Partition 3 is for common
areas between partitions 1 and 2). Then press *.
 Report Code (RC) should be left at 01. The summary will show 10 though
this is correct. Press * to continue
 Enter Hardwire Type (HW).
o If you used a resistor enter 0
o Normally Closed=1
o NO=2
o Press * to continue
o Response Time should be left at 1. Press * to continue.
Use * to continue and # is to back up