Step 8: Confirmation of Arming Ding (*38) (Page 4-2 in the Installation and
Setup Guide)
Note: You do not need to enter *38 if you have just completed step 7.
Enter:
o 00=No Ding
o 01=Ding after Arming
o 02=Ding after arming with RF button or RF keypad
Step 9a: Hardwired Zone Programming (*56) (Page 5-1 and 5-2 of the
Installation and Setup Guide)
Enter *56
Set to Confirm will be displayed on the screen. This means: Are you
installing wireless devices?
o
0=NO and 1=Yes
Zone 1 is for Fire or any hardwired device if fire is not being used
Zones 2-8 hardwired devices
Zones 9-48 Wireless Transmitter Zones
Zones 49-64 Key Fobs
Zone 92 Duress
Zones 95, 96, and 99 are Panic Zones
Zone Types:
00= Not Used 04= Interior follower 08= 24 Hr Aux 21= Arm-Away
01=Entry/Exit #1 05=Trouble Day/Alarm Night 09=Fire no delay 22=Disarm
02=Entry/Exit #2 06=24 Hr Silent 10=Interior delay 23=No Alarm Response
03=Perimeter 07=24 Hr Audible 20=Arm Stay 24=Silent Burglary
Enter the Zone Number you wish to program and press *. A summary
screen will be displayed. Press * again to advance past the summary
screen.
Enter the Zone Type (ZT). (Refer above or go to page 5-2 in the
Installation and Setup Guide for the exact types). Press * to continue.
Enter the partition number (PT 1 or 2). (NOTE= Partition 3 is for common
areas between partitions 1 and 2). Then press *.
Report Code (RC) should be left at 01. The summary will show 10 though
this is correct. Press * to continue
Enter Hardwire Type (HW).
o If you used a resistor enter 0
o Normally Closed=1
o NO=2
o Press * to continue
o Response Time should be left at 1. Press * to continue.
Use * to continue and # is to back up