NOTE: DO NOT hook power to the keypad until the entire system is installed and
ready for programming. Reason: You have to make a programming change to
each keypad upon 30 seconds of power being sent to the keypad.
Upon 50 seconds of power up, you will need to press and hold * and # at
Exit Programming=*99 or 00 depending on where you are at
Step 1: Assign Keypad Address
Within 30 seconds of the main keypad receiving power: Press and hold
the 1 and 3 buttons at the same time.
Con Addr = will appear and you will need to enter 16. Then press *
On each additional keypad you will need to enter a unique address: 17,
18, etc.
o Do Not Duplicate Keypad Addresses. Keypads have to be
addressed 16 to 23 (no duplicates), but come defaulted at 31 and
will not work until they are re-addressed.
Step 2: Enter Programming
After the keypad is addressed, you will need to enter programming:
Enter 4112 800
Field 20 (Installer Code) will be displayed on the screen.
We can begin programming from this point.
Step 3: Default the Entire System (*97)
Enter *97 to default your system. The system will beep. This will ensure
that there is a clean slate to start from.
If you will be using central station monitoring: Press *96 and the system
will beep. This is for clearing the ID number for Central Station.
Step 4: Installer Code (*20)
If you would like to change the installer code, press *20 + new installer
code. Be sure not to forget this number.
Quick Start Guide
Vista-20P
Installer Code = 4112
Master Code=1234
Program Mode= 4112+800
Or
same time.
*=Change Data
#=View Data