The colours of the wires may vary depending on the float switch supplied
Float Switch
Float Switch
2
Input Connections for Float/Pressure Switch
(2 channel version)
1
SMS Dialler
Connecting the float/pressure switch:
The float switch comes with a flex mounded into the float head. If
required the length of this cable can be extended using a 3 core 1mm²
electrical flex and a suitable junction box. The colours of the wires may
vary depending on the float switch supplied. Connect one side of the
float switch to GND and the other to IPA, this will trigger an SMS text
when float switch (1) activates. If fitting a second float switch or a
pressure switch connect one side to GND (this is a common connection)
and the other side to IPB. This will send a different text message when
either the float or pressure switch activates.
IP A
IP B
GND