HiBoost F10G-5S-LCD Kullanıcı Kılavuzu - Sayfa 8

Genişletici HiBoost F10G-5S-LCD için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. HiBoost F10G-5S-LCD 18 sayfaları.

HiBoost F10G-5S-LCD Kullanıcı Kılavuzu
coverage.
"Power dBm"– Power Indication.
The displayed value shows real-time downlink power that the amplifier is delivering
to the indoor antenna port. When the amplifier DL output power is lower than
-10dBm, the value will display "---".
"ISO" – Isolation Alarm Indication.
When the system does not have enough isolation between the outdoor and indoor
antennas, the "ISO" indicators will be flashing showing that the ISO is lowering the
gain in some bands to keep the system from oscillating. Press the "SET" key and the
LCD screen will display "ISO" showing the current band or bands affected.
"ALC" Flashing.
When the amplifier is receiving too much DL power from the tower and the DL
amplifier output is close to saturating, the "ALC" indicators will flash showing that
the ALC has lowered the gain to prevent this overload condition. Press the "SET"
button and the screen will show the band or bands affected.
"OFF"- Booster shut-off alarm indication.
In some rare situations the ALC or ISO will not be able to compensate for an
oscillation condition or a downlink overload. When this happens the amplifier
will shut off in the affected band and the LCD "OFF" indicator will flash. Pressing
the "SET" button will display which band or bands are affected.
https://www.signalbooster.com/ | 1-855-846-2654 | [email protected]