Dynamic RS4 Kurulum Talimatları ve Tüketici Bilgileri - Sayfa 6
Hava Temizleyici Dynamic RS4 için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Tüketici Bilgileri indirin. Dynamic RS4 9 sayfaları. Whole house iaq system
10) For 407H-16-O3 ONLY – Plug the 120 VAC power cord into an outlet which is interlocked with
the furnace blower. If an EAC terminal is available, supply power to the outlet from the EAC
terminal. If there is no EAC terminal, interlock the UV unit with the furnace blower using an
appropriate alternate.
11) Verify voltage is operating between 120 - 240 VAC when the air handler is operating.
12) Replace and secure cover using the two retaining nuts. Affix caution labels if necessary.
Figure 8 – Safety Switch (side view)
NOTE: CARE SHOULD BE TAKEN TO ENSURE THAT UVC LIGHT DOES NOT SHINE
ON PLASTIC SURFACES INCLUDING WIRING.
Section V. Maintenance – Air Cleaner Media Pads
Air cleaner media pads generally last 3 to 4 months, depending on household conditions. In
a new installation, however, it is suggested that the media pad be inspected and/or replaced
after one month of operation due to initial cleanup of contaminants. Only GENUINE
replacement media pads should be used with your air cleaner. Failure to do so could cause
damage to the air cleaner, alter air cleaner performance, and/or void your Warranty.
Replacement media pads are available from your heating and air conditioning contractor.
CAUTION: WHENEVER INSTALLING OR REMOVING THE AIR CLEANER, THE POWER
TO THE FURNACE/AIR HANDLER SHOULD BE TURNED OFF. CARE SHOULD BE
TAKEN NOT TO LET THE JACK TOUCH ANY GROUNDED OR METAL SURFACES.
1) Turn the thermostat fan switch to the "OFF" position.
2) Turn off power to the furnace/air handler.
3) Turn off power to UV air purifier and disconnect power cord (if applicable).
4) Open the access panel on the RS4 cabinet.
5) Unplug the power cord from the air cleaner power supply.
6) Remove the air cleaner from the filter rack.
7) Open the air cleaner latches, carefully remove the old media pad, and discard.
8) Carefully position the new replacement media pad so that it is centered within the air
cleaner frame.
9) Close and re-latch the air cleaner.
10) Return the air cleaner to its location in the filter rack.
11) Plug the power supply cord into the air cleaner once it is securely in place (fig 6).
Safety
Switch
Screw
Safety
Switch
Lamp Holder
Figure 9 – Lamp Back Mounting Plate
6
Safety
Switch