Autonics BYD DDT Series Ürün Kılavuzu - Sayfa 2

Güvenlik Sensörleri Autonics BYD DDT Series için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. Autonics BYD DDT Series 5 sayfaları. Photoelectric sensors with built-in timer

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
BYD
-
❶ Sensing distance
Number: Sensing distance (unit: mm)
Number+M: Sensing distance (unit: m)
❷ Sensing type
T: Through-beam
D: Diffuse reflective
D: Convergent reflective
❸ Power supply
D: 12 - 24 VDCᜡ
❹ Output
T: Solid state (transistor)
Sold Separately
• Bracket B
• M12 connector cable: C□D(H)4-□-□
Cautions during Installation
• Be sure to install this product by following the usage environment, location, and specified
ratings. Consider the listed conditions below.
- Installation environment and background (reflected light)
- Sensing distance and sensing target
- Direction of target's movement
- Characteristic curves
• When installing multiple sensors closely, it may result in malfunction due to mutual
interference.
• For installation, tighten the screw with a torque of 0.5 N m. Mount the brackets correctly to
prevent the twisting of the sensor's optical axis.
• Do not impact with a hard object or bend the cable excessively. That could decrease the
product's water resistance.
• Use this product after the test. Check whether the indicator works appropriately for the
positions of the detectable object.
Through-beam
Emitter - Receiver:
Install to face each other
Timer Setting
• In case of the built-in timer model, you can set the OFF Delay timer.
(adjustable time: 0.1 to 2 sec)
• Use the offered adjustment screwdriver. Do NOT turn with excessive force to prevent product
damage.
Min.
Max.
Operation Timing Chart and Indicators
■ Standard type
Operation mode
Light ON
Received
Received light
Interrupted
ON
Operation
indicator (red)
OFF
ON
Transistor output
OFF
• In case of the through-beam type, to prevent malfunction, output of units keeps the state of OFF
for 0.5 sec after power ON.
■ Built-in timer type
Operation mode
Light ON
Received
Received light
Interrupted
ON
Operation
indicator (red)
OFF
ON
Transistor output
OFF
• T: Setting time by the adjuster (setting time: 0.1 to 2 sec)
• t: ≤ 3 ms (When the adjuster is set to Min (0.1 sec))
• If the interrupted time (Ta) after receiving the light is shorter than the setting time (T),
the transistor output maintains the ON state.
-
-
-
❺ Connection
No mark: Cable type
W: Cable connector type
❻ Control output
No mark: NPN open collector output
P: PNP open collector output
(Through-beam type)
❼ Feature of convergent reflective type
No mark: Front operation indicator
U: Upper operation indicator
T: Built-in timer (OFF delay mode)
• Slit for through-beam type: BYD3M-ST (sticker)
Reflective
Sensor - Sensing target:
Install to face each other (parallel with the
sensing side of the unit)
Dark ON
Received
Interrupted
ON
OFF
ON
OFF
Ta
t
T
t
T
Connections
■ Cable type
• Emitter
• Receiver (BYD3M-TDT2-□), Diffuse reflective,
(BYD3M-TDT1-□)
Convergent reflective type
Brown
NPN
Blue
01) Through-beam type: max. 100 mA, diffuse reflective or convergent reflective type: max. 50 mA
■ Cable connector type
2
3
Circuit
■ NPN open collector output
OCP
SCP
01) Through-beam type: max. 100mA, diffuse reflective or convergent reflective type: max. 50 mA
• OCP (over current protection), SCP (short circuit protection)
• If short-circuit the control output terminal or supply current over the rated specification, normal control signal is
not output due to the protection circuit.

Sensitivity Adjustment

• Set the adjuster for stable Light ON area, minimizing the effect of the installation environment.
• Use the offered adjustment screwdriver. Do NOT turn with excessive force to prevent
product damage.
• The steps below are based on Light ON mode.
STEP Status
Description
01
Received
02
Interrupted
03
-
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
• This dimensions shows the cable type.
Refer to the 'Specifications' for the core, wiring and connector.
12.4
A
Ø3.5, 2m
Through-beam
A
Optical axis
B
Upper operation indicator of convergent reflective type (red)
C
Sensitivity adjustment adjuster or timer adjuster of built-in timer model
■ Bracket A
14
8
6
Brown
Brown
LOAD
Black
Black
PNP
01)
Blue
Blue
Pin
Color
Brown
1
-
Blue
4
Black
• Connector pin ④ is N.C (not connected) terminal
for the emitter.
■ PNP open collector output
LOAD
OCP
SCP
01)
Turn the adjuster from MIN to MAX sensitivity and
check the position (A) where the operation indicator
activates under the light ON area.
Turn the adjuster from (A) to MAX and check the
position (B) where the operation indicator activates
under the light OFF area.
If the operation indicator does NOT activate at the
MAX (maximum sensitivity): MAX = (B).
Set the adjuster at the mid position between (A) and
(B) for optimal sensitivity.
B
18
12.4
3
Ø3.5, 2m
Diffuse reflective,
Convergent reflective
25
21.5
12
C4
Max. 100 mA
LOAD
Function
+V
-
0 V
OUT
Max. 100 mA
LOAD
C