AUTOPILOT SYSTEMS Pool Pilot Digital Kullanıcı El Kitabı - Sayfa 10

Aydınlatma Ekipmanları AUTOPILOT SYSTEMS Pool Pilot Digital için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. AUTOPILOT SYSTEMS Pool Pilot Digital 16 sayfaları. Swimming pool and spa purification system

Section 3a – OPERATION
Use UP/DOWN ARROW to scroll through sub-menu and SELECT to choose function:
3.1 Test: same as 1.0 above plus cell Amp-hrs – then returns to Main Menu
3.2-3.4 Set Time of Day: same as 2.4 above
3.5 Force Reverse: allows you to check cell volts and amps in the opposite direction (verifies reversing feature)
3.6 Set Reverse Time: allows adjustable self-cleaning reverse rate of 2, 4, 8 or 16 hrs; Back – Main Menu (3.0)
Cell reversal is set on 4-hrs from the factory for ideal cell life. For conditions such as high calcium levels that can
cause the cell to scale quicker than the self-cleaning cycle can control, change the setting to "2" hours.
For pools with optimum water chemistry balance according to the Saturation Index, see page 10, changing the
REVERSING cycle to "8" or "16" hours will extend the life of the cell.
If the Reverse Time is set to the "16" hours setting, check the cell weekly for the first month to ensure no scale
Note: changing the Reversing Time to "2" hours will affect the cell life. However, operating with scale
development on the cell is more damaging to the life of the cell and changing the reversing time is suggested
3.7 Calibrate Salt: allow you to calibrate the salt display. Contact the factory for calibration solution
3.8 Replace Cell: zeros the amp-hour counter. Only used when replacing cells. Hold Select for 13 seconds to reset
3.9 Back – Main Menu (returns to MAIN MENU)
INSTALLER MENU text switching from the lower of the two line display, to the upper of the display)
Use UP/DOWN ARROW to scroll through sub-menu and SELECT to choose function:
4.1 English/Metric: displays volume in gallons or cubic meters; salt additions as lbs or kg; Back – Main Menu (4.0)
4.2 Temperature Units: displays the water temperature in Fahrenheit or Celsius; Back - Main Menu (4.0)
4.3 12/24-hour Time: displays the current time in 12-hour Time or 24-hour Times units; Back – Main Menu (4.0)
4.4 Set Pool Volume: displays the volume of the pool in either Gallons or Cubic Meters
4.5 Set Cell Power: allows you to set the Power Level = 1, 2 or 3; Back – Main Menu (4.0)
4.6 Set Pump Config: allows you to select from External Timer, One-Speed Pump, Two-Speed Pump, or Remote
Runs Pump configuration
4.7- 4.9 Set Time of Day: same as 2.4 – 2.6 above
4.10 Back – Main Menu (returns to MAIN MENU)
* Software version 4.2 and newer allows the programming of Select Minerals: which will display "Minerals" or "Salt"
Error Messages / "CHECK SYSTEM" light illuminated (see Troubleshooting section, page 15, for more details):
If the message "Purifier Off" is shown, the system halts purifier production. This is shown when the flow is insufficient.
If the message "Warning!" is shown, the system will continue to produce purifier but at a reduced efficiency. This is
associated with a correction message and flashing Check System light.
P u r i f i e r
12:00P
Boost
3.0 MAINTENANCE MENU
develops. If there is scale development, change the setting to "8" hours.
4.0 INSTALLER MENU
(Hold Select for approximately 13 seconds to enter this mode, indicated by the
D i g i t a l
100%
ON
80F
Menu
Select
Pump
9
Key Features – Con't
Check
System