ASSEMBLY
STEP 1. Find a safe location. Minimum clearance from the ceiling and the mantel must be at
least 8 inches (200mm); minimum clearance from the front must be at least 3 feet (900 mm).
Choose a location near an outlet so an extension cord is not required. DO NOT position the unit
directly below a power outlet. See Safety Information on pages 3 and 4 for more warnings
about placement, installation, and use of this product.
MODEL
A
STEP 2. Take model EF173B as an example. Prepare a wall with a framed opening of 44 5/16"
(1125mm) wide × 18 1/8" (460mm) high. Make sure the width of the wood block on both sides
which used to fix the fireplace is 3". (76mm) Make sure that the revealed wood block width on
both sides is about 1 1/2"(37.5mm) after finishing the plasterboard. Measure the depth D from the
plasterboard surface to the wood block and write it down.
DY-BT48
EF173B
36 7/16"
44 5/16"
(925mm)
(1125mm)
DY-BT60
EF175B
56 1/8"
(1425mm)
(1625mm)
7
EF176B
64"
79 3/4"
(2025mm)