Major tech MT935 Kullanım Kılavuzu - Sayfa 7
Ölçüm Cihazları Major tech MT935 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Major tech MT935 8 sayfaları. Phase rotation meter with rotary field direction
Ayrıca Major tech MT935 için: Kullanım Kılavuzu (8 sayfalar)
8.2. Non-Contact Rotary Field Indication
Function
Frequency Range (fn)
8.3. Determine the Motor Connection
Function
Nominal Test Voltage (U me)
Nominal Test Current (In per phase) Less than 3.5mA
Frequency Range (fn)
8.4. Electrical Specifications
Function
Battery
Current Consumption
Battery life Minimum
8.5. Safety Specifications
Function
Electrical Safety
Maximum Operating Voltage (Ume) 400V AC for all ranges
Protection Levels
8.6. Environmental
Function
Operating Temperature
Operating Humidity
Operating Altitude
Pollution Degree
Type of Protection
8.7. Mechanical Specifications
Function
Size (HxWxD)
Weight (With the battery)
Range
2 to 400Hz
Range
1 to 400V AC
2 to 400Hz
Range
9V alkaline, IEC 6LR61
Max 20mA
1 year for average use
Range
Meets DIN VDE 0411,IEC 61010
DIN, VDE 0413-7, IEC 61557-7/EN
61557-7
CAT III 1000V and CAT IV 600V
Range
0°C to 40°C
15% to 80%RH
2000m
2
IP40
Range
135x75x31mm
174g
7