5. Operation

5.1. Auto Power Off

The meter automatically turns off after 15 minutes of inactivity. To reset the
meter after it shuts off, turn rotary function switch to the off position and than
set the switch to the desired function. To disable Auto Power Off, turn the rotary
function switch to the off position. Press and hold the MODE button and set the
rotary function switch to the desired function except switch set to current.
Release the MODE button when the "
Auto Power Off is now disabled. Auto Power Off will be restored when the meter
is turned off and back on again.

5.2. MODE Button

Used to select AC or DC voltage, Hz or % Duty Cycle, Ohms, Diode Test,
Continuity or Capacitance, and °F and °C.

5.3. MAX MIN Button

1.
Momentarily press the MAX/MIN button to activate the MAX/MIN mode. The
"MAX" indicator will appear on the LCD display. The meter will display and
hold the maximum reading and will update when a higher "max" occurs.
2.
Momentarily press the MAX/MIN button to view the lowest reading. The
"MIN" indicator meter will appear on the LCD display. The meter will display
and hold the minimum reading and will update when a lower "min" occurs.
3.
Press and hold the MAX/MIN button to end MAX/MIN and return to normal
operation.
NOTE: The meter does not auto range when the MAX/MIN mode is active. The
display will read "OL" if the range is exceeded. MAX/MIN does not work on
Frequency, Duty Cycle, Diode Test, Continuity and Capacitance.

5.4. Flashlight Button

Press the
button to turn the flashlight on and off.

5.5. HOLD/Backlight Button

To freeze the reading on the display, momentarily press the HOLD
"HOLD" will appear on the LCD display while the reading is being held.
Momentarily press the HOLD
The backlight illuminates the LCD display when the ambient light is too low to
view the displayed readings. To turn on, press and hold the HOLD
the backlight turns on. To turn off, press and hold the HOLD
the backlight turns off.
" symbol on the LCD display disappears.
button again to return to normal oper ation.
button.
button until
button again until
7