KitchenAid KGCV566RMT01 Kurulum Talimatları Kılavuzu - Sayfa 4
Setüstü Ocak KitchenAid KGCV566RMT01 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. KitchenAid KGCV566RMT01 17 sayfaları. Gas built-in cooktops
GaS $U
Explosion
Hazard
Use a new AGA or CSA approved
gas
supply
line.
Install
a shutoff
valve.
Securely
tighten
all gas connections.
[f connected
to LP, have a qualified
person
make
sure
gas pressure
does
not exceed
14" water
column.
Examples
of a qua[flied
person
include:
licensed
heating
personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure
to do so can result
in death,
explosion,
or fire.
Observe all[ governing
codes and
ordinances.
iMPORTANT: Cooktop must be connected
to a reguHated gas suppHy.
Am
This instaHHafion must conform
with HocaHcodes and ordinances.
Hnthe
absence of [oca[ codes, instaHHations must
conform
with American
National
Standard,
National
Fuel Gas Code ANSI
Z223.1 -- latest edition +_ or CAN[ --
B149.1 or 2+__+,
input
ratings
shown
on the
model/serial
rating
plate
are for
elevations
up to 2,000
feet (610 m). For
elevations
above
2,000
feet (610 m),
ratings
are reduced
at a rate of 4% for
each
1,000
feet (305 m) above
sea level.
C
m The cooktop
is equipped
for use
with
natural
gas +, It is design-certified
by
CSA international
for natural
and L.R
gases with
appropriate
conversion.The
model/serial
rating
plate,
located
on
the underside
of the burner
box,
has
information
on the type
of gas that can be
used.
If this information
does
not agree
with
the type
of gas available,
check with
the local
gas supplier.
See Page 2 for L.R
gas conversion
instructions.
m Provide
a gas supply
line of 3/4"
rigid
pipe
to the cooktop
location.
A
smaller
size pipe
on long
runs
may
result
in insufficient
gas supp[%
Pipe+joint
compounds,
suitable
for use with
LR
gas, must
be used. With
LR gas,
piping
or tubing
size can
be 1/2" minimum.
L.R
gas suppliers
usually
determine
the size
and materials
used
on the system.
E
m [f local
codes
permit,
a newAGA
or CSA design-certified,
4% foot
(1.2ol.5
m) long,
1/2" or 3/4" I.D., flexible
metal
appliance
connector
is recommended
for
connecting
this cooktop
to the gas supply
line.
Do not kink or damage
the flexible
connector
when
moving
the cooktop.The
pressure
regulator
has 3/8" female
pipe
threads.You
will
need to determine
the
fittings
required,
depending
on the size of
your
gas supply
line, flexible
metal
connector
and shutoff
valve.
to cooktop
_-_
gas supply
F
line
m The supply
line shall
be equipped
with
an approved
shutoff
valve.This
valve
should
be located
in the same
room
as the cooktop
and should
be in a
location
that
allows
ease
of opening
and
closing.
Do not block
access
to the
shutoff
valve.The
valve
is for turning
on
or shutting
off gas to the appliance.
fittings
must
be used to obtain
an in-line
connection
to the cooktop.
A[[ strains
must
be removed
from
the supply
and
fuel
lines
so cooktop
will
be level
and in
line+
mThe regulator
must be checked at
a minimum
1-inch (2.5 cm) water column
above the set pressure.The
inlet pressure
to the regulator
should
be as follows
for
operation
and checking the regulator
setting:
NATURAL
GAS:
Set pressure 4 inches (10.2 cm).
Supply
pressure 7-14 inches (17.8 cm
to 3&5 cm) maximum.
LR GAS:
Minimum
pressure 10 inches (25.4 cm).
Supply
pressure
14 inches (35.5 cm).
m Line
pressure
testing:
Testing
above
1/2 psi (3.5 kPa)
(14 inches
(3&6
cm)) W.C.
(gauge)
The cooktop
and its individual
shutoff
valve
must
be disconnected
from
the gas
supply
piping
system
during
any
pressure
testing
of that
system
at test
pressures
greater
than
1/2 psig (3.5kPa).
Testing
below
1/2 psi (3.5 kPa) (14 inches
(35.6 cm)) W.C_ (gauge)
or lower
The cooktop
must
be isolated
from
the
gas supply
piping
system
by closing
its
individual
manual
shutoff
valve
during
any pressure
testing
of the gas supply
piping
system
at test
pressures
equal
to
or less than
1/2 psig
(3.5 kPa).
Electrical
Shock
Hazard
Plug
into
a grounded
3 prong
outlet.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure
to foimow these
instructions
can
result
in death,
fire, or electrical
shock.
If codes
permit
and a separate
ground
wire
is used,
it is recommended
that
a
qualified
electrician
determine
that the
ground
path
is adequate.
Check
with
a qualified
electrician
if you
are not sure
whether
the cooktop
is
properly
grounded.
Do not ground
to a gas pipe.
A 120+volt,
60-Hz,
AC+only,
15-ampere,
fused
electrical
supply
is required.
A
time-dehy
fuse
or circuit
breaker
is
recommended.
It is recommended
that a
separate
circuit
serving
only
this
appliance
be provided.
_Exception:
Model
KGCR055 is
manufactured
for use with L.R gas onl!i.
*_National
Fire Protection
Association
One Batterymarch
Park
Quincy, Massachusetts
02269
_**CSA
International
8501 East Pleasant Valley Rd+
Cleveland,
OH 44131+5575