For service convenience,
a shut-off valve (not supplied) should be installed in the supply line in a readily accessible
location (such as beneath the sink) and a union (not supplied) should be installed in the supply line near the
dishwasher
fill valve.
-
CAUTION -
To prevent heat damage to the fill valve, ALL solder connections
must be made BEFORE the water line is
connected
to the dishwasher.
DRAIN LINE
The drain line should be 9/16" ID (minimum) flexible hose or 5/l' OD copper tubing. Flexible hose must be resistant
to heat and detergent and may be obtained from a plumbing,
hardware, or automotive supply outlet. DO NOT use
any fittings anywhere in the drain line that are less than l/z" ID. The access hole for the drain line should be 1".
If drain line is copper, clamp a 12" length of s6" ID flexible hose (heat and detergent resistant) to the end of the
copper tubing. This will facilitate connection
of the drain line to dishwasher
check valve.
If the drain line is going to be connected
to a food waste disposer,
BE SURE to remove the knockout
or
plug from the fitting
on the disposer
before connecting
drain line. Rubber adapter fitting
may be required.
(KitchenAid
part number
115729 or available
from local hardware
or plumbing
stores.)
Typical drain connections
to sink plumbing
are shown
Illal" 01 d,sprer connecllon
in Fig. 5 & 6.
Fig.
5
Fig.
6
Typical drain connection
to an air gap (if required by local code) are shown in Fig. 6.
If drain is rounted to a connection
point less than 20" above the floor, the drain line MUST be made to form
a high loop tube (shown
in Fig. 7).
CAUTION:
Failure to provide either the proper drain connection
height (20" above floor level) or a 20" high
loop will result in improper
draining
of the machine
which
may cause damage to the machine.
To form the high loop tube, see inset on Fig. 7. Make sure that no kinks develop in the hose or copper tubing.