Troubleshooting:
Cabinet Temperature is too Warm:
Thermostat set too warm.
Airflow blocked.
Excessive amount of warm product placed in
cabinet.
Fuse blown or circuit breaker tripped.
Dirty condenser coil.
Evaporator coil iced over.
Low refrigerant levels.
Door is slightly ajar.
Condensation is Collecting on the Cabinet and/or Floor:
Relative humidity is above 60%
Gasket it not sealing properly.
www.AvantcoRefrigeration.com
User Manual
Commercial Sandwich Prep Tables
Set thermostat to lower temperature.
Re-arrange product to allow for proper air
flow. Make sure there is at least four inches of
clearance from evaporator.
Allow adequate time for product to cool down.
Replace fuse or reset circuit breaker.
Clean the condenser coil.
Ensure doors are closed when not in use.
Avoid opening doors for long periods of time.
Contact a service technician to check
refrigerant levels.
Make sure door is completely closed.
Move unit to area below relative humidity or
lower humidity level.
Clean, repair, or replace the gasket as
necessary.