Installation Guide
The installation process normally takes between 1 and 2 hours. The installation can be completed by
one person but 2 people working together can simplify the installation process. It is recommended to
have a plumber or any technical person having done some plumbing work to install the unit. In some
places, building department permits may be necessary for the installation. Since the water in the water
tank is in high pressure and high temperature, use your own judgments in installing the unit yourself.
AirGenerate
recommends use of only licensed plumbers to install AirTap
™
please follow all safety measures provided by your water heater company.
Safety Information
(Please read this section carefully to prevent accidents or injuries).
The following precautions are recommended to prevent electrical shocks:
• Disconnect power before installing the AirTap
• Ensure that the power receptacle is rated for 115V and at least 15A. Make sure no other appliance is sharing this outlet.
• Ensure that the electrical supply has proper overload fuse or breaker protection.
• Ensure that wire sizes and connections comply with all applicable codes.
The following precautions are recommended to prevent chemical accidents:
• Wear eye protection during the installation. If the copper tubing is ruptured, the refrigerant used in the AirTap
cause burns.
• When the AirTap
is running, do not bend the copper tubing because the refrigerant may leak and cause severe burns.
™
• In case of leaks, do not breathe the refrigerant. Ventilate the area and vacate for at least one hour.
The following precaution is recommended to prevent injuries:
• The AirTap
system weighs 48 lbs. All lifting should be done with caution and assistance if available to prevent back injuries.
™
• For people who suffer from back problems, a second person should assist.
The following precaution is recommended to prevent accidents:
• If the pressure relief valve on the existing water heater tank is leaking or dripping, call a licensed plumber for repair.
Do not plug or remove valve. Failure to follow this instruction could result in an explosion.
The following precautions are recommended to prevent other possible accidents:
• Water temperature over 125
• Follow all safety instructions provided by the manufacturer of the existing water heater.
Tools required for the installation:
• Adjustable 14" pipe wrench
• 12" Adjustable wrench
• 6" Adjustable wrench
• Phillips screwdriver
• Safety gloves
• Safety glasses
• A Level
™.
F can cause severe burns instantly resulting in severe injury or death.
˚
Inside the AirTap
• The AirTap
• Thermal insulation for heating coil
• Drain hose
• 2 mounting brackets
• 3/4" nipple tube
• 3/4" Flange adaptor
• 3/4" T adaptor
• Teflon Tape
package, you will find:
™
water heater unit
™
. In addition to this guide,
™
may
™
3