AirGenerate airtap Kurulum Kılavuzu - Sayfa 2

Su Isıtıcı AirGenerate airtap için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. AirGenerate airtap 8 sayfaları.

AirTap
Product Description
Overview
The AirTap
water heater uses heat pump technology to convert energy extracted from air to heat water. This simple-to-use
and virtually maintenance-free water heater saves energy consumption by about 70% and reduces monthly energy bills.
The AirTap
unit plugs directly into an existing gas or electric water heater, and utilizes its own supply of electricity as the
energy source to operate the low-wattage compressor that harvests the air energy.

Technical Specifications

Specifications: (Ambient Temp. 68˚F)
Max water temp:
130˚F (10˚ F between open and close)
Efficiency
240%
Energy Factor
2.11
First Hour Rating
43 Gallons
Output
7000 BTUs
Dimensions
18" x 14" x 14" (height)
Weight
48 lbs
System Requirements
The AirTap
can only be placed indoors. If using the unit in an attic, garage or basement, the unit can be installed
without any additional equipment. However, if using the device in a space with less than 1,000 cubic feet, an external
vent will likely be necessary as well as ductwork to direct the cool air expelled from the unit. A duct kit can be purchased
from AirGenerate
.
CAUTION: If the AirTap
shares space with a fireplace or gas appliance, it must be vented to draw air from the outside to
prevent back-drafting, a serious fire hazard.
The AirTap
connects to a typical household outlet, 115V, 15A. While the device requires about 12A initially upon power
up, the device draws 7A on average during operation. It is recommended that a dedicated 15A circuit be used to power
the AirTap
. It is important to reserve the outlet solely for the AirTap unit, as shortage may occur.
The AirTap
is recommended for tanks between 30 and 80 gallons. The system is easiest to install in tanks which are at least
35 inches tall.
A drain must be available to accommodate condensate generated by the AirTap
condensation can amount to as much as 1 quart per day. The condensate can be routed to the outside or expelled into
a plumbing vent pipe, by way of a drainhose included with the AirTap
Warnings
When installing the AirTap
water heater while the AirTap
remain disconnected after installation.
When installing the AirTap
is being installed.
Before installing the AirTap
properly secured.
2
on a gas or electric water heater, disconnect permanently the gas or power supply to the
is being installed. The original gas/power supply to the gas/electric water heater shall
on a gas or electric water heater, please do not use the water heater while the AirTap
on the existing water heater, make sure that the water heater is on a flat surface and
Electrical Specifications
Volts
115
Amps
12 initial surge/6 operating
Phase
1
Frequency
60 Hz
. In high humidity environments this
.