AirGenerate airtap Посібник з монтажу - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник з монтажу для Водонагрівач AirGenerate airtap. AirGenerate airtap 8 сторінок.
AirTap
Product Description
™
Overview
The AirTap
water heater uses heat pump technology to convert energy extracted from air to heat water. This simple-to-use
™
and virtually maintenance-free water heater saves energy consumption by about 70% and reduces monthly energy bills.
The AirTap
unit plugs directly into an existing gas or electric water heater, and utilizes its own supply of electricity as the
™
energy source to operate the low-wattage compressor that harvests the air energy.
Technical Specifications
Specifications: (Ambient Temp. 68˚F)
Max water temp:
130˚F (10˚ F between open and close)
Efficiency
240%
Energy Factor
2.11
First Hour Rating
43 Gallons
Output
7000 BTUs
Dimensions
18" x 14" x 14" (height)
Weight
48 lbs
System Requirements
The AirTap
can only be placed indoors. If using the unit in an attic, garage or basement, the unit can be installed
™
without any additional equipment. However, if using the device in a space with less than 1,000 cubic feet, an external
vent will likely be necessary as well as ductwork to direct the cool air expelled from the unit. A duct kit can be purchased
from AirGenerate
.
™
CAUTION: If the AirTap
shares space with a fireplace or gas appliance, it must be vented to draw air from the outside to
™
prevent back-drafting, a serious fire hazard.
The AirTap
connects to a typical household outlet, 115V, 15A. While the device requires about 12A initially upon power
™
up, the device draws 7A on average during operation. It is recommended that a dedicated 15A circuit be used to power
the AirTap
. It is important to reserve the outlet solely for the AirTap unit, as shortage may occur.
™
The AirTap
is recommended for tanks between 30 and 80 gallons. The system is easiest to install in tanks which are at least
™
35 inches tall.
A drain must be available to accommodate condensate generated by the AirTap
condensation can amount to as much as 1 quart per day. The condensate can be routed to the outside or expelled into
a plumbing vent pipe, by way of a drainhose included with the AirTap
Warnings
When installing the AirTap
™
water heater while the AirTap
remain disconnected after installation.
When installing the AirTap
™
is being installed.
Before installing the AirTap
properly secured.
2
on a gas or electric water heater, disconnect permanently the gas or power supply to the
is being installed. The original gas/power supply to the gas/electric water heater shall
™
on a gas or electric water heater, please do not use the water heater while the AirTap
on the existing water heater, make sure that the water heater is on a flat surface and
™
Electrical Specifications
Volts
115
Amps
12 initial surge/6 operating
Phase
1
Frequency
60 Hz
. In high humidity environments this
™
.
™
™