Fronius KD Supply 2500 Kullanım Talimatları Kılavuzu - Sayfa 11

Kaynak Sistemi Fronius KD Supply 2500 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Fronius KD Supply 2500 16 sayfaları.
Ayrıca Fronius KD Supply 2500 için: Kullanım Talimatları Kılavuzu (20 sayfalar)

Fronius KD Supply 2500 Kullanım Talimatları Kılavuzu
Connecting the KD Supply 2500 to the cold wire
feeder, commissioning
Connecting the
KD Supply 2500
to the cold wire
feeder, commis-
sioning

Commissioning

Power for the KD Supply 2500 is supplied by the power source
1
2
3
4
a)
b)
Connect the power source and the cold wire feeder using the interconnecting hosep-
ack
Connect the welding torch
Carry out steps 1 and 2 as described in the power source and cold wire feeder oper-
ating instructions
Plug in the power source mains lead
Turn power source mains switch to position „I"
The KD Supply 2500 is now ready.
Connect the LocalNet cable or the
1
LocalNet cable from the interconnect-
ing hosepack to the LocalNet interface
of the cold wire feeder
Connect the LocalNet cable or the
2
LocalNet cable from the interconnect-
ing hosepack to the KD Supply 2500:
a)
LocalNet X9.2 interface (front) or
b)
LocalNet X9.3 interface (rear)
11