Care, maintenance and disposal

General remarks

Under normal operating conditions the KD Supply 2500 requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the
welding system remains in a usable condition for many years.
Danger from electrical current.
This can result in serious personal injury and damage to property.

Every start-up

-
-
-
-

Every 6 months

-
Danger due to the effect of compressed air.
This can result in damage to property.

Disposal

Dispose of in accordance with the applicable national and local regulations.
12
WARNING!
Before starting work, switch off all devices and components involved and disconnect
them from the grid.
Secure all devices and components involved so they cannot be switched back on.
After opening the device, use a suitable measuring instrument to check that electric-
ally charged components (such as capacitors) have been discharged.
Check welding torch, interconnecting hosepack and ground earth connection for
signs of damage
Perform a visual check on the feed rollers and inner liners for signs of damage
Check contact pressure of feed rollers and adjust if necessary
Check brake and adjust if necessary
Dismantle device side panels and clean inside of device with dry, reduced com-
pressed air
CAUTION!
Do not bring the air nozzle too close to electronic components.