Cosel KHNA240F Kullanım Kılavuzu - Sayfa 5

Güç Kaynağı Cosel KHNA240F için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Cosel KHNA240F 9 sayfaları. Ac-dc power supplies din rail type

4 Temperature
Measurement Point
¡ Ambient temperature indicates the temperature of the inlet of the
air.
Airflow
Fig.4.1 Ambient temperature measurement point
¡ Temperature of Forced air
Use the temperature measurement point as shown in Fig.4.2 to
4.3. Please use at the temperature dose not exceed the values in
Table 4.1. Please also make sure that the ambient temperature
does not exceed 70C.
¿ KHEA30F, KHNA30F
TB2
POINT B
(C515)
TB1
Fig.4.2 Temperature measurement point (Forced air)
¿ KHEA60F, KHNA60F
TB2
POINT B
(C516)
TB1
Fig.4.3 Temperature measurement point (Forced air)
AC-DC Power Supplies DIN Rail Type
Ambient temperature
measurement point
POINT C
(T201)
POINT A
(C106)
POINT C
(T201)
POINT A
(C107)
¿ KHEA90F, KHNA90F
TB2
POINT B
*
(C515)
TB1
* P lease be careful of electric shock or earth leakage in case of temperature measurement,
because POINT A and POINT B is live potential.
Fig.4.4 Temperature measurement point (Forced air)
Table 4.1 Specified temperature of the measurement point
No.
Model
1
KHEA30F, KHNA30F
2
KHEA60F, KHNA60F
3
KHEA90F, KHNA90F
OUTPUT
INPUT
Fig.4.5 Installation removing chassis and case
Thermocouple for temperature checking must be added into tem-
perature measuring point after removing chassis and case.
Then assembling chassis and case again, the temperature can be
measured.
Chassis and case are fixed in 4 parts which are shown in the figure.
Please contact us about detail.
¡ Temperature of Forced air
Use the temperature measurement point as shown in Fig 4.6.
Please use at the temperature does not exceed the values in
Table 4.2.
Please also make sure that the ambient temperature does not ex-
ceed 70C.
June 29, 2020
Instruction Manual
Temperature measurement point
Point A
Point B
80C
80C
80C
80C
80C
80C
CASE
4- JOINT PART
CHASSIS
POINT A
*
(C106)
Point C
105C
105C
KH-25