Alish AM5H-A Kullanıcı Kılavuzu - Sayfa 4
Ölçüm Cihazları Alish AM5H-A için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Alish AM5H-A 5 sayfaları. 5 digital micro-process meter with 2~4 alarms / analog output / rs-485
Display
System Setting Page (SYS)
Press
E
Select decimal point (0, 1, 2, 3, 4).
Decimal Point
Setting (dP)
EX: if the value shows "0.00" that means the decimal point is 2 digits.
Press
Modify display low scale for the input signal zero value.
E
Display Low Scale
EX: If the input signal is 4~20mA; 4mA is shown display 0.00,
Setting (dSPL)
this parameter must be set for 000.00.
Press
E
Modify display high scale for the input signal span value.
Display Hi Scale
EX: If the input signal is 4~20mA; 20mA is shown display 100.00,
Setting (dSPH)
this parameter must be set for 100.00.
Press
E
Modify display average (1~99).
Display Average
PS: Please use this function for stable display value
Setting (AvG)
when input signal is unstable.
Press
E
Display Low Cut
Modify display low cut to 0 (0~99).
Setting (LCUt)
Press
E
Modify pass code (0~19999).
Pass Code
PS: Please don't forget the new pass code after modification.
Setting (CodE)
Press
E
Control DI
Select control DI off(YES) or on(NO).
PS: Control DI (Z, MAX, HD) & (COM) shorts, the functions starts.
Setting (di)
Lock the keys, using key lock function
Press
E
Key Lock
only can view the parameters, but cannot modify any values.
Setting (LoCK)
PS: no (unlock) ,YES ("ENT" unlock , others lock).
Press
E
Alarm Setting
The following steps are only available for alarm output.
Page (roP)
Press
E
Alarm 1
(ACt1)
Alarm 2
(ACt2)
Modify alarm value that is (Hi) or <(Lo) for alarm action.
Alarm 3
(ACt3)
Alarm 4
(ACt4)
Press
E
Hysteresis 1
(HYS1)
Hysteresis 2
Modify the value, when alarm runs lower or higher
(HYS2)
display value (depends on alarm action).
Hysteresis 3
Alarm setpoint this range (0~999) will turn off the alarm.
(HYS3)
Hysteresis 4
(HYS4)
Press
E
Delay Time 1
(dEL1)
Delay Time 2
Modify the value, when the display value reach the alarm
(dEL2)
value that need to wait for this time
Delay Time 3
(0~99 sec) for alarm action.
(dEL3)
Delay Time 4
(dEL4)
Press
E
Alarm Start Band
Modify the value (-99~+99), if the display value don't over
Setting (Sb)
this range; the alarm will not be act.
Press
E
Modify the value (0~99 sec), if the display value reach alarm
Alarm Start Band
start band value; the alarm will be act after this value (sec).
Time Setting (Sdt)
(The function is used with "Sb" function.)
Press
E
AM5H-A
Descriptions
System Setting Group Procedures
Alarm Setting Group Procedures
>
=
+ -
P3
Default
Customers
A/O Setting Page
specify
(AoP)
Customers
Press
E
A/O Polarity
specify
Setting (PoLAr)
Customers
Press
E
A/O Low Scale
specify
Setting (AnLo)
Press
E
A/O Hi Scale
Setting (AnHi)
Press
E
RS485 Setting
Page (doP)
Press
E
Address Setting
(Addr)
Press
E
Baud Rate
Setting (bAUd)
Press
E
Parity Setting
(PAri)
Press
E
Frame Setting
(FrAmE)
Press
E
Display
**Please check the wiring connection is correct first, if the problem still exist, please return the meter
to the factory.
AM5H-A
Descriptions
Display
A/O Setting Group Procedures
The following steps are only available for analog output.
Select output for positive or negative pole.
PS : Voltage output ,NO: positive pole output (0~+10V)
YES: positive & negative pole output (-10~+10V)
Adjust A/O low scale to correspond to the display value.
EX : A/O is 0~10V, the display is 10.0 to output 0V,
this value must be set for 10.0.
Adjust A/O hi scale to correspond to
the display value (programmable).
EX : A/O is 0~10V, the display is 90.0 to output1 0V, this value must be set for 90.0.
RS485 Setting Group Procedures
The following steps are only available for RS-485.
Modify address (0~255).
Select baud rate (38400/19200/9600/4800).
Select parity (n.8.2/n.8.1/even/odd).
Select frame type. ( NO:Hi
Error Code of Self-Diagnosis
Descriptions
Input signal is over 120% of input range.
Input signal is under -20% of input range.
Input signal is over 180% of input range or meter error.
Input signal is over display range (99999)
Input signal is under display range (-19999)
EEPROM reading/writing suffers the interference (about 1 million times).
P4
Default
Lo , YES:Lo
Hi )