Fujitsu PRIMERGY RX200 S6 Servis Ek Kılavuzu - Sayfa 34
Sunucu Fujitsu PRIMERGY RX200 S6 için çevrimiçi göz atın veya pdf Servis Ek Kılavuzu indirin. Fujitsu PRIMERGY RX200 S6 50 sayfaları.
Replacement routines
4.5
Replacing the HDD backplane
I
The following description applies to both variants of HDD backplanes (6x
HDD modules or 8x HDD modules).
Removing the defective HDD backplane
Ê Open the server as described in the
page
23.
Ê Remove all HDD modules (see the Operating Manual).
V
CAUTION!
Ensure that all HDD modules are uniquely identified so that you can
reinsert them into their original bays after replacing the HDD
backplane.
Figure 14: Removing the HDD backplane
Ê Disconnect all cables from the HDD backplane (see circle).
Ê Lift the HDD backplane over the metal bars (see arrows) and then remove it.
Installing the new HDD backplane
Ê Place the new HDD backplane on the metal bars (see arrows in
and press it down carefully.
Ê Reconnect the cables to the HDD backplane (see the cabling plans in the
Appendix of the Options Guide).
Ê Reinstall all HDD modules (see the Operating Manual).
34
section "Opening/closing the server" on
Service Supplement
figure
14)
RX200 S6