Replacing a riser card

There are three different riser cards:
– Riser card #1: PCIe x8, standard and low-profile expansion cards
– Riser card #2: PCIe x8, only low-profile expansion cards
– Riser card #3: PCIe x4, internal, only for (low-profile) RAID controllers
I
The following description applies to all variants of riser cards.
Removing the defective riser card
Ê Open the server as described in the
page
23.
Figure 16: Position of riser card holders 1-3
Ê If necessary, disconnect the cables from the relevant expansion card.
Ê Lift the required riser card holder upward and remove it.
Ê Remove the expansion card from the PCI slot of the riser card (description
see the Options Guide).
RX200 S6
2
1
Service Supplement
Replacement routines
section "Opening/closing the server" on
3