Front of the Server Unit

2.2.2 Indicators on the operating panel

ID
12
ID indicator (blue)
Lights up blue when the Server Unit has been selected by pressing the ID
button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView Operations Manager
and the iRMC web interface, and its status can be reported to the ServerView
Operations Manager and the iRMC.
Status indicator (green)
Does not light up when the Server Unit is switched off but connected to the
power supply (power cable connected).
Lights up green during power up and when operating normally (S0).
Status indicator (power cable connected) (green)
on the right-hand side of the On/Off switch
Does not light up in the following cases:
The Server Unit is not connected to the power source
The Server Unit is switched on and operating normally (S0)
Lights up green when one of the following cases occurs:
The Server Unit is switched off but connected to the power supply (power
cable connected)
The Server Unit is switched on but is in the power up delay
I
After the Server Unit has been connected to the power source, it takes
approximately 60 seconds until the Server Unit has entered standby
mode.
HDD activity indicator (green)
Lights up green when an internal hard disk drive is being accessed.
Server Unit SU300