Fujitsu 5530C2 - fi - Document Scanner Başlarken - Sayfa 25

Tarayıcı Fujitsu 5530C2 - fi - Document Scanner için çevrimiçi göz atın veya pdf Başlarken indirin. Fujitsu 5530C2 - fi - Document Scanner 28 sayfaları. Color departmental scanner
Ayrıca Fujitsu 5530C2 - fi - Document Scanner için: Teknik Özellikler (2 sayfalar)

Appendix2
When operating the scanner, the
ARNI N G
ADF's inside glass becomes very
hot.
Before you clean inside the scan-
ner, turn off its power and unplug
the AC adapter from the outlet. Wait
for at least 15 minutes.
Do not turn off the scanner when
you clean the Feed rollers or Eject
rollers.

■ Cleaning Materials

Cleaning
Parts No.
Materials
Cleaner F1
PA03950-
0352
Lint-free dry
- Commercially available one
cloth
For details about the cleaning materials, contact the
FUJITSU scanner dealer where you purchased the scan-
ner.

■ Cleaning Method

The ADF must be cleaned with a lint-free cloth moist-
ened with the Cleaner F1.
It may take long before the cleaner
ATTENTION
vaporizes if a large quantity is used.
When cleaning the scanner parts,
dampen a cloth with modest quantities
of the cleaner. In addition, wipe off the
cleaner completely with a soft lint-free
cloth to leave no residue on the surface
of the cleaned parts.
DAILY CARE
Remarks
1 bottle
Moisten a cloth with
this fluid and wipe the
scanner clean.
fi-5530C Image Scanner Getting Started
■ Locations and Cycle for Cleaning
Part to clean
Pad ASSY
Pick roller
Feed rollers
Plastic rollers
Eject rollers
Sheet guides
Glass
Ultra sonic sensor
The scanner must be cleaned more fre-
ATTENTION
quently if you scan any of the following
type of sheets:
Documents of coated paper
Documents that are almost completely
covered with printed text or graphics
Chemically treated documents such
as carbonless paper
Documents containing a large amount
of calcium carbonate
Documents written by pencil
Documents on which the toner is not
fused sufficiently.
For details on the cleaning the ADF, refer to section 3.2
"Cleaning the ADF" of "fi-5530C2 Operator's Guide"
on the Setup CD-ROM."
Standard Cleaning Cycle
Clean these parts after every
5,000 scans.
AP-4