1 Installation
1.1 Connection/Power-On
Carefully remove the board from the shipping carton.
First, check if there are any damages before powering up the evaluation board.
For the power supply a DC input voltage of 9V – 15V is recommended. The positive
voltage (+) must be connected to the center pin, and ground (GND) must be
connected to the shield of the connector X12!
After power-on (JP43), the orange power-on LEDs (D16, D17 and D18) should be lit. If the
LEDs do not light up, switch off the power supply and check input polarity and current
capability of the DC supply used. Please do not look directly into the LEDs to prevent
harming your eyes.
The in-circuit programming allows the user to program own applications into the Flash
memory. The procedures for Flash programming are described in chapter 4.
If the board shall be used as an emulator target board, switch off the power supply and
remove the microcontroller from the socket. Now the probe cable can be mounted on the
socket. Take care of the pin 1 marking on the socket and fasten the probe cable with the
provided screws.
Do not use any other probe cable than MB2198-510-E only!
Connect the probe cable to the MB2198-500 emulation Adapter Board. Check all jumper
settings of the evaluation board, the Probe Cable, and the Adapter Board.
When turning on the system, be sure to use the following power-up sequence:
1. Power up the Emulator Main Unit (MB2198-01)
2. Power up the Adapter Board (MB2198-500), if needed
3. Power up the target Board (SK-96390-100PMC)
To turn off the system, switch off the components in reverse order, beginning with the target
Board.
Please refer to the corresponding user manuals and application notes for the emulator how
to set up the emulator system. After power on the 'UVCC'-LED of the emulator must be on.
Note:
Some customers experience connectivity problems when connecting the MCU into
the socket adapter. Only the small red screwdriver available in your box should be
used to connect the cover (HQPACK) onto the socket (NQPACK).
If the four screws are not tightening equally, then it may cause a poor contact.
Do not screw the cover too tight (max 0.054 Nm). If you have connectivity problems
then please loosen the screws and tighten again the screws equally.
Do not clean NQPACK, YQPACK, and YQSOCKET with steam. Cleaning material will
contaminate inside of connector.