Shaker type dust collector
16

MAINTENANCE AND INSPECTION

The chart indicated below shows different inspections and the frequency at which they should be
performed.
Frequency of
inspections
Daily
Dust collector
Filter envelope
Weekly
Automatic shaker
Semi-annually/
Dust collector
Annually

17 TROUBLESHOOTING

Problem
Smoke or dust
escaping from the
clean air outlet
Drop in filter
efficiency
Components
Probable cause
Filter envelope not
installed correctly
Leak in filter envelope
Damaged seal
Shaker system not
fuctioning correctly
High level of humidity
within the collector
Procedures
Examine air outlet for possible dust or smoke
accumulation. Refer to Troubleshooting section.
Check for leaks on the filter enveloppe. Repare or
replace if necessary. Ensure the filter enveloppe is
securely fastened.
Examine the shaker mechanism for any unusual
noise or vibration, broken parts or loose components.
Examine, clean and apply paint touch-ups if necessary.
If needed, lubricate the shaker and shaft rocking
system using lithium base grease.
Tighten fasteners on filter frame
to ensure proper seal.
Repair or replace filter envelope.
Repair or replace seal.
Examine the shaker system (motor, reducer, shaft,
frame) Repair or replkae if necessary. Increase
frequency of shaker actions.
Check humidity level or relative humidity within the
collector. A slightly higher humidity level may be cor-
rected by closing some gates and starting the cleaning
cycle. If the humidity level is too high, take necessary
measures to dry the air before it enters the collector.
Solution
16