Aqua Quip QC Series Kurulum Talimatları ve Kullanım Kılavuzu - Sayfa 2
Yüzme Havuzu Aydınlatması Aqua Quip QC Series için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım Kılavuzu indirin. Aqua Quip QC Series 4 sayfaları. Surface-mounted led retro-fit pool light
Ayrıca Aqua Quip QC Series için: Kurulum Talimatları ve Kullanım Kılavuzu (4 sayfalar)
Step 2: Quick-Connect Plug Kit Installation
Before starting: The Quick-Connect Plug Kit is supplied pre-assembled with a WHITE Seal. A RED and a BLACK
Seal is also provided in the kit. Use the correct Seal for the application, depending upon the diameter (thickness)
of the existing pool light cable, as represented below:
Red Seal – Suits THIN cables: Diameter 6mm - 7mm (gauge 0.75mm² - 1mm²)
White Seal – Suits STANDARD cables: Diameter 7mm - 7.5mm (gauge 1.5mm²)
Black Seal – Suits THICK cables: Diameter 8mm - 9mm (gauge 2.5mm² - 4mm²)
The Quick Connect Plug Kit can only be connected to cables with a round profile, do not connect the plug kit to
"figure 8" building wire.
A) Strip back the end of the existing cable as follows:
For STANDARD and THICK Cables:
Bare back 14mm of wire sheath,
then expose 7mm of copper wire.
For THIN Cables
1) Bare back 21mm of wire sheath.
2) Expose 14mm of copper wire, then bend
copper wire back on itself, doubling it up so
it is 7mm long.
B) Remove protective Cable Cap by disengaging the
two clips on the Cable Bracket. Slide cable through
the rear of the pre-assembled Quick Connect
Plug Kit, you may have to loosen the Cable Nut to
enable the cable to slide through.
D) Slide Female Plug into the Connector Housing. Be sure to align the keyway on the Female Plug with the
keyway on the inside of the Connector Housing. Push all the way down.
2
QC SERIES SURFACE MOUNTED LED RETRO-FIT POOL LIGHTS – INSTALLATION INSTRUCTIONS & OWNERS MANUAL
QC SERIES
Exposed Wires
Exposed Wires
C) Insert wires into terminals on Female Plug and
Female Plug
Cable Nut
Cable Bracket
Keyway
SURFACE MOUNTED LED
RETRO-FIT POOL LIGHT
7mm
7mm
Existing STANDARD or THICK Cable
Wire Sheath
14mm
7mm
Wire Sheath
Exposed Wires
Wire Sheath
doubled over
tighten screws all the way down using #1 Phillips
screwdriver. (If not tightened correctly the plug will
be difficult to fit into the Connector Housing).
Connector Housing
Existing THIN Cable
Existing THIN Cable