Aqua Science Fleck 2510 SXT Digital Kurulum Kılavuzu - Sayfa 10

Su Filtrasyon Sistemleri Aqua Science Fleck 2510 SXT Digital için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Aqua Science Fleck 2510 SXT Digital 12 sayfaları. Digital water softener system

Fleck 5600 SXT Digital Water Softener System Installation Manual
Fleck 5600 SXT Digital Programming (continued)
800-767-8731
Step 6
The next setting you'll see is C (Capacity). Set to the capacity of your system.
Refer to the chart at the bottom of the Parts List page to match tank size to proper filtration
media amount.
Press the Cycle button to advance to the next step.
Step 7
The next setting you'll see is H (Hardness). Refer to your water test information for this
value. Valves should be in GPG (grains per gallon). Note: 1 GPG = 17.1 Mg/L
Press the Cycle button to advance to the next step.
Step 8
The next setting you'll see is RS (Reserve Selection). Set the value to SF.
Press the Cycle button to advance to the next step.
Step 9
The next setting you'll see is SF (Safety Factor). The number value you see refers to
percentage of reserve at which your system will regenerate. For example if you have a
system that provides 1000 gallons of soft water and you set the Safety Factor to 15 (15%),
after you've used 85%, your system will regenerate (RT - step 11) vs. using all 1000
gallons before it regenerates.
Press the Cycle button to advance to the next step.
Step 10
The next setting you'll see is DO (Day Override). Set this to 14.
Press the Cycle button to advance to the next step.
10