CPG 351SRCPG36NL Kullanıcı Kılavuzu - Sayfa 4

Menziller CPG 351SRCPG36NL için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. CPG 351SRCPG36NL 9 sayfaları. Countertop step-up ranges

CPG 351SRCPG36NL Kullanıcı Kılavuzu
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL

Installation Instructions

NOTE: Installation must be performed by a licensed service technician.

INSTALLATION

1 . Choose a location under a ventilation hood, see "Exhaust System" for more details. Also ensure that
the unit will maintain the proper clearances as shown the spec table above.
2 . Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand.
Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with
legs mounted, lift if necessary to move unit.
3 . There must be adequate clearance for removal of the front panel. All major parts except the
burners are removable through the front if the gas line is disconnected.

GAS CONNECTION

1 . Ensure gas supply and gas type, as shown on unit nameplate, match. The nameplate is located on
the side panel.
24" Step-Up Countertop Range/Hot Plate
Lancaster, PA
4003027
2 . Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
National Gas Installation Code, CSA‐B149.1, or the Propane Installation Code, CSA‐B149.2 as
applicable and in accordance with local codes.
3 . Use pipe threading compound or tape to seal all gas connections. Pipe threading compound must
be resistant to the action of liquefied petroleum gases.
4 . DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water
solution before operating unit.
4
w/ 4 High-Output Burners
Item: 351SRCPG24NL
Gas Type: Natural BTU: 120,000
Ori ce Size: #43
Manifold Pressure: 6" WC
Conforms to ANSI STD
Serial #:
Z83.11b-2009 (R2011)
Conforms to CSA STD
1.8b-2009 (R2011)
Intended for commercial use only.
NSF Tested by ETL
MADE IN CHINA
www.cookingperformancegroup.com
.