Configuration Coupons - Continued
Insert the configuration coupon and verify the settings were accepted by counting the bezel flashes
Bezel LED Error Flash Codes
When the unit is ready and enabled, the bezel LEDs will flash continuously. If the bezel LEDs are off, the unit has an error. To determine the error, partially insert
and hold a bill in the bill path until the bezel lights flash. Count the flashes and refer to the chart below.
Talos Install Guide_Web_5.24.19.indd 3
Flashes
Meaning
Configuration coupon accepted and unit
10
successfully programmed.
Coupon rejected. Number of flashes corresponds
1 - 5
to the coupon section that was improperly filled
out. Try again.
Coupon not read. Confirm the coupon is
7
correct and try again.
Flashes
Problem
None
No power
1 or 4
Bill path
blocked
2
Another
vending
component
3
Lower
housing
assembly
5
Bill magazine
removed
Continuous
Stacker full
fast
Continuous
Unit is
slow
defective
Solution
Restore power to validator or machine
Check for jams. Remove bill
magazine and lower housing
assembly and inspect
Ensure the unit has been enabled,
then check:
• Vending Machine Controller
• Coin manager and coin levels
• Inventory levels
• The door is locked properly
Check that the lower housing
assembly is seated. Ensure bill path
is clean; see Cleaning section
Reattach bill magazine
Empty the bill magazine
Replace the unit